Fluorat-02-series analyzers
Fluorescence Analyzer Fluorat-02-4М/5М
Fluorat-02 is a multifunctional filter fluorometer intended for quantitative analysis of different types of samples, including water, soil, and food.
The instrument determines a wide range of organic or inorganic analytes based on fluorescence, chemiluminescence, phosphorescence, and photometry techniques.
Fluorat-02-series analyzers
Fluorat-02 is a multifunctional filter fluorometer intended for quantitative analysis of different types of samples, including water, soil, and food.The instrument determines a wide range of organic or inorganic analytes based on fluorescence, chemiluminescence, phosphorescence, and photometry techniques.
Both FLUORAT-02-4M and FLUORAT-02-5M models are capable of fluorescence, chemiluminescence and photometry measurements.
FLUORAT-02-4M also provides phosphorescence measurement using the time-resolved gating fluorometer mode. In particular, this mode is used to determine uranium and is characterized by a very high sensitivity and selectivity.
FLUORAT-02-5M can operate as a nephelometer for measuring turbidity.
- Low detection limit
- Fast analysis with low reagent consumption
- Determination of a large variety of analytes
- 4-in-1 instrument: fluorometer, chemiluminometer, photometer, and nephelometer
- High analytical selectivity compared to conventional photometirc instruments
- COD-analyzer (Chemical Oxygen Demand), when equipped with Termion thermoreactor
- FluoRate software complies with FDA 21 CFR part 11
WATER
- Total petroleum hydrocarbons (TPH)
- Anionic surfactants
- Chemical Oxygen Demand (COD)
- Fluorescein
- Aluminium
- Arsenic
- Boron
- Nitrites
- Uranium (for Fluorat-02-4M model only)
- Zinc
- Turbidity
SOIL
- Total petroleum hydrocarbons (TPH)
FOOD AND FEED
- Vitamin B1 (thiamine)
- Vitamin B2 (riboflavin)
- Selenium
PHARMACEUTICALS
- Aluminium
FluoRate software provides easy-to-use tools to control Fluorat-02-4M and Fluorat-02-5M analyzers as well as to process obtained data by fluorescence, phosphorescence and photometric methods.
The software complies with all requirements of FDA 21 CFR Part 11 of the Code of Federal Regulations of the United States Food and Drug Administration (FDA).
- Fluorat-02 analyzer (base set includes quartz cells, optical filters and FluoRate Software);
- Kits for analysis (on request);
- TERMION (thermoreactor for COD analysis).
Fluorat-02 analyzer is covered by a full 1-year warranty.
Installation and commissioning can be carried out at a customer site by our service engineers or by certified distributor service engineers.
Wavelength range (filter selection) |
250–650 nm (Fluorat-02-4M) 250–900 nm (Fluorat-02-5M) |
Detection limit | 5 μg/L (phenol) |
Types of cells | quartz (L=10 mm) glass vials for COD |
Power supply | 110-240 VAC, 50/60 Hz, 36 W |
Dimensions (LxWxH) | 305x320x110 mm |
Weight | 6,5 kg |